Convenience for reading
Compared with other exam files our E20-554 learning materials: Isilon Design Specialist Exam for Technology Architects own three versions for you to choose: namely the PDF version, the App version as well as the software version of E20-554 test braindumps. No matter whom you are and where you are, you will find one version most suitable for you. For example, if you are the busy person, you can opt to the App version or PDF version of E20-554 practice exam materials to study in the spare time so that it will much more convenient for you to do exercises with your mobile phones. What's more, as the E20-554 test dumps: Isilon Design Specialist Exam for Technology Architects can be printed into paper version it will be good to you as you can make notes on it in case of the later review. With our EMC E20-554 pass-for-sure materials, you can make full use of your fragmented time, such as time for waiting for bus, on the subway or in the break of work.
High pass rate
Actually, high pass rate is what all those making exam files are always in pursuit of. Yet, not every one of them can eventually attain this lofty goal. However, our E20-554 test braindumps do achieve it. According to the statistics collected from the recent years, our E20-554 learning materials: Isilon Design Specialist Exam for Technology Architects have achieved the high pass rate of 98% to 99%. No other certification training files can take place of our E20-554 study guide as this kind of good impression is deeply rooted in the minds of people. The high pass rate is, frankly speaking, attributed to high quality of our exam files. With our high-qualified EMC E20-554 exam preparation: Isilon Design Specialist Exam for Technology Architects, to pass the exam is just like a piece of cake. As a clever person, I bet you must be aware of the fact that it is less likely to take risks by using exam files with a high pass rate. Then why not have a try?
Maybe you have ever felt perplexed about your future because you can't pass the exams to get certificates that are a must for you to get involved in your longing field even after you have spared no efforts. But I would like to say, the past has gone with the wind because you will turn a new leaf after using our EMC E20-554 learning materials: Isilon Design Specialist Exam for Technology Architects. Why? The reasons are as follows.
Considerate services
Considerate services for our E20-554 learning materials: Isilon Design Specialist Exam for Technology Architects can be referred to as a large shining point. The word "considerate" can be understood with regard to the following two points. Firstly, our staff of the E20-554 test braindumps stays to their posts online around the clock. No matter when you have questions to ask, you can get immediate answers which are not only to the point, but also polite. Secondly, our experts who give priority to the renewal of our EMC E20-554 test dumps: Isilon Design Specialist Exam for Technology Architects will immediate send the renewal to our customers the moment they have discovered any of it. With such considerate service, no wonder our EMC E20-554 test braindumps have enjoyed great popularity by the general public.
After purchase, Instant Download: Upon successful payment, Our systems will automatically send the product you have purchased to your mailbox by email. (If not received within 12 hours, please contact us. Note: don't forget to check your spam.)
EMC E20-554 Exam Syllabus Topics:
| Section | Objectives |
|---|---|
| Topic 1: Isilon Architecture and Components | - Data layout and striping methodology - Node types and cluster design - OneFS architecture fundamentals |
| Topic 2: Cluster Design and Sizing | - Scale-out design principles - Performance considerations - Capacity planning and workload assessment |
| Topic 3: Networking and Protocols | - Network topology design - NFS, SMB, and multiprotocol environments - Client access optimization |
| Topic 4: Data Protection and Availability | - Protection levels and mirroring strategies - Snapshot and backup integration - Disaster recovery design |
| Topic 5: System Management and Operations | - Monitoring and maintenance - Security and access control - Upgrades and lifecycle management |
EMC Isilon Design Specialist Exam for Technology Architects Sample Questions:
1. You are asked to size a cluster for a file sharing environment. nfsstat indicates that no more than 10% of the requests are namespace operations (e.g. GETADDR, SETADDR). There will be 10,000 active Linux users, connecting over NFS.
Which cluster configuration would you recommend?
A) Ten X200 (27 TB) 48 GB RAM, 600 GB SSD, N+2:1
B) Five X400 (120 TB) 96 GB RAM, 2.4 TB SSD, N+2
C) Eight X200 (36 TB) 24 GB RAM, no SSD, N+2:1
D) Ten X400 (60 TB) 48 GB RAM, 2.4 TB SSD, N+2:1
2. Your customer has observed a degradation in response time while browsing for media files within the Production Media folder on the Isilon cluster. That directory now contains over five million files. It was confirmed that there are no network or edit station related causes.
What changes to the Isilon cluster will best accelerate the browsing performance?
A) Upgrade network interfaces on the nodes to 10 Gbps
B) Upgrade RAM on the nodes
C) Add an A-Series Performance Accelerator node
D) Add Solid State Drives (SSDs) to the nodes
3. A customer has grown 2 PB in the last year. The cluster performs well most times of the day, but occasionally during the day, the customer notices a decrease in performance. You have been told that 'tree-deletes' are taking too long and can only be run on weekends.
What would you recommend to speed up the 'tree-deletes'?
A) Use an A100 node for added CPU performance to help with 'tree-deletes.'
B) Add an SSD node tier for metadata to account for at least 2% of RAW capacity
C) Add an SSD tier for metadata, ensuring all nodes have SSDs.
D) Add 20% more nodes to the cluster to help with degraded performance.
4. A potential customer requires 4 PB of usable capacity to store media files. The workloads are a combination of streaming video delivery and long term archive of video assets.
There is very little space available in the customer's datacenter, so physical density is very important. The customer is concerned about performance impact and potential data loss when using 3 TB or larger drives.
What Isilon capabilities can address the customer's concerns?
A) Isilon nodes have more drives per rack unit so fewer shelves are required.
Proactive hot sparing eliminates most drive rebuilds.
N+3 and N+4 Protection Levels exceed traditional RAID6 availability.
B) Isilon does not perform rebuilds - data reprotection is typically 2x-3x faster than traditional RAID
rebuilds.
N+3 and N+4 Protection Levels exceed traditional RAID6 availability.
Data redistribution runs faster with more nodes in the cluster.
C) Isilon does not perform rebuilds - data reprotection is typically 2x-3x faster than traditional RAID
rebuilds.
Data recovery is consistent, taking the same amount of time regardless of cluster size.
Isilon 'short strokes' 4TB drives to reduce rebuild time.
D) N+3 and N+4 Protection Levels exceed traditional RAID6 availability.
Proactive hot sparing eliminates most drive rebuilds.
Endurant Cache reduces the overhead for write operations.
5. In your second meeting with the customer you ask the following questions about their current unified SAN and NAS platform.
"Are you using an application to map users from NFS Exports to SMB shares? Is each site a separate LDAP or AD Domain?"
What functionality are you trying to understand in their environment and what is the comparable feature in IsilonOneFS?
A) Identity Mapping and Authentication Sources
B) User Management and AD Authentication
C) NFS Export Management and OneFS Cluster Management
D) Kerberos Infrastructure and Identity Management
Solutions:
| Question # 1 Answer: A | Question # 2 Answer: D | Question # 3 Answer: B | Question # 4 Answer: B | Question # 5 Answer: A |



